# Virtual Chassis
A virtual chassis represents a set of devices which share a common control plane. A common example of this is a stack of switches which are connected and configured to operate as a single device. A virtual chassis must be assigned a name and may be assigned a domain.
A virtual chassis represents a set of devices which share a common control plane. A common example of this is a stack of switches which are connected and configured to operate as a single managed device. Each device in the virtual chassis is referred to as a VC member, and assigned a position and (optionally) a priority. VC member devices commonly reside within the same rack, though this is not a requirement.
Each device in the virtual chassis is referred to as a VC member, and assigned a position and (optionally) a priority. VC member devices commonly reside within the same rack, though this is not a requirement. One of the devices may be designated as the VC master: This device will typically be assigned a name, services, virtual interfaces, and other attributes related to managing the VC.
If a VC master is defined, interfaces from all VC members are displayed when navigating to its device interfaces view. This does not include other members interfaces declared as management-only.
One of the member devices may be designated as the VC master: This device will typically be assigned a name, services, virtual interfaces, and other attributes related to managing the VC. If a VC master is defined, interfaces from all VC members are displayed when navigating to its device interfaces view. This does not include management-only interfaces belonging to other members.
!!! note
It's important to recognize the distinction between a virtual chassis and a chassis-based device. A virtual chassis is **not** suitable for modeling a chassis-based switch with removable line cards (such as the Juniper EX9208), as its line cards are _not_ physically autonomous devices.
It's important to recognize the distinction between a virtual chassis and a chassis-based device. A virtual chassis is **not** suitable for modeling a chassis-based switch with removable line cards (such as the Juniper EX9208), as its line cards are _not_ physically autonomous devices. Instead, use [modules](./module.md) for these.
## Fields
### Name
The virtual chassis' name.
### Domain
The domain assigned for VC member devices.
### Master
The member device which has been designated as the chassis master (optional).