# Racks
|
||||
|
||||
The rack model represents a physical two- or four-post equipment rack in which equipment is mounted. Each rack must be assigned to a site. Rack height is measured in *rack units* (U); racks are commonly between 42U and 48U tall, but NetBox allows you to define racks of arbitrary height. A toggle is provided to indicate whether rack units are in ascending or descending order.
|
||||
The rack model represents a physical two- or four-post equipment rack in which devices can be installed. Each rack must be assigned to a site, and may optionally be assigned to a rack group and/or tenant. Racks can also be organized by user-defined functional roles.
|
||||
|
||||
Each rack is assigned a name and (optionally) a separate facility ID. This is helpful when leasing space in a data center your organization does not own: The facility will often assign a seemingly arbitrary ID to a rack (for example, "M204.313") whereas internally you refer to is simply as "R113." A unique serial number may also be associated with each rack.
|
||||
Rack height is measured in *rack units* (U); racks are commonly between 42U and 48U tall, but NetBox allows you to define racks of arbitrary height. A toggle is provided to indicate whether rack units are in ascending (from the ground up) or descending order.
|
||||
|
||||
Each rack is assigned a name and (optionally) a separate facility ID. This is helpful when leasing space in a data center your organization does not own: The facility will often assign a seemingly arbitrary ID to a rack (for example, "M204.313") whereas internally you refer to is simply as "R113." A unique serial number and asset tag may also be associated with each rack.
|
||||
|
||||
A rack must be designated as one of the following types:
|
||||
|
||||
@@ -12,4 +14,12 @@ A rack must be designated as one of the following types:
|
||||
* Wall-mounted frame
|
||||
* Wall-mounted cabinet
|
||||
|
||||
Each rack has two faces (front and rear) on which devices can be mounted. Rail-to-rail width may be 19 or 23 inches.
|
||||
Similarly, each rack must be assigned an operational status, which is one of the following:
|
||||
|
||||
* Reserved
|
||||
* Available
|
||||
* Planned
|
||||
* Active
|
||||
* Deprecated
|
||||
|
||||
Each rack has two faces (front and rear) on which devices can be mounted. Rail-to-rail width may be 10, 19, 21, or 23 inches. The outer width and depth of a rack or cabinet can also be annotated in millimeters or inches.
|
||||
|